E Activation of the highvoltage end if ignition sparks are not triggered

The ignition trigger signal can be simulated for rapid troubleshooting at the ignition end. For this purpose, connect the oscilloscope tester lead terminal 4 to the ignition lead from the ignition coil to the high-voltage distributor (terminal 4).

Disconnect the DME control unit plug. Switch on ignition.

If a battery voltage is now applied intermittently to terminal 1 of the control unit plug with a test lead (e.g. control unit plug terminal 18), a high-voltage peak must be displayed on the oscilloscope each time (ignition triggering).

DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.