1979 Porsche 928 Fuel Pump Delivery Rate

TESTING AND ADJUSTING SPECIFICATIONS FOR CIS ( 197 8/1979 Models Automatics)

Test

Specification

Electric fuel pump Delivery rate with 1 fuel pump with 2 fuel pumps at least 1120 cc/30 sec. at least 1360 cc/30 sec.

Control pressure "cold" (= ambient temperature)

Diagram for control pressure regulator Part No. 928.606.109, 02 Bosch No. 0438. 140. 053 Test vacuum 430 - 600 mbar (350 - 450 mmHg)

Remarks

Control pressure "warm"

Test with pressure (without vacuum)

Vacuum pump connected on intake connection of control pressure regulator, test pressure of 460

mmHg)

With

Porsche Classic Models

Porsche Classic Models

The History of Porsche Cars through its generational changes. A must have ebook for any Porsche fanatic, this ebook is a reference book for Porsche enthusiasts. Discover all there is to know about the greatest Porsches ever made. All models are fully described and illustrated providing a definitive production history plus an accurate guide to original specs and equipment.

Get My Free Ebook