5. Measure play between 2nd and 3rd gears. Nominal value: 0.1 to 0.35 mm. If this tolerance cannot be reached, recheck adjustment of synchronizer.

6. Measure axial play on 4th gear with a feeler gauge blade and adjust with a pertinent circlip. Play should be between 0.20 and 0.35 mm, whereby lower value would be ideal.

1. Clean synchronizer rings and gears.

Circlips available:

Part Number

Thickness (mm)

Was this article helpful?