Test point

Oil cooler blower relay Detectable faults: Short to positive

Note

Fault code 57

Monitoring of control lead to cooler blower relay

(G10 Central Electrical System).

1) Check Tiptronic control unit connector/pin 49 to relay base/termial TF for short to positive. (Observe connection to A/C control unit).

2) Check connection form relay base/terminal TF to cooling-water temperature switch for short to positive.

3) On vehicles with air conditioning, check connection from relay base/terminal TF to pressure switch/air conditioning for short to positive.

Porsche Classic Models

Porsche Classic Models

The History of Porsche Cars through its generational changes. A must have ebook for any Porsche fanatic, this ebook is a reference book for Porsche enthusiasts. Discover all there is to know about the greatest Porsches ever made. All models are fully described and illustrated providing a definitive production history plus an accurate guide to original specs and equipment.