Crash signal

The airbag control module emits a signal to the alarm system control module no later than 35 seconds after Term. S is switched on and until Term. S is switched off again. This signal has a frequency of 10 Hz and indicates two states -normal state (live signal) and crash state. The two states differ in the pulse/duty ratio of the

Live signal 20% high 80% low

Crash signal 80% high 20% low

Signal evaluation begins 45 seconds after term. S is switched on. If no signal is detected from the airbag control module, a corresponding fault is entered into the fault memory.

Porsche Classic Models

Porsche Classic Models

The History of Porsche Cars through its generational changes. A must have ebook for any Porsche fanatic, this ebook is a reference book for Porsche enthusiasts. Discover all there is to know about the greatest Porsches ever made. All models are fully described and illustrated providing a definitive production history plus an accurate guide to original specs and equipment.