Fault code

Calibration not carried out yet

This fault is stored in the following case:

1. A newly installed control module has not be calibrated yet Elimination:

- Select menu item Calibration.

Follow instructions on the screen and carry out the calibration Note:

Calibration is not possible if the sensor voltage lies outside the plausible range (sensor voltage less than 2 V or greater than 3 V).

Check the sensor voltages in menu item Actual values, with the vehicle parked on a level surface (vehicle not raised)

Check sensor holder and linkage

Porsche Classic Models

Porsche Classic Models

The History of Porsche Cars through its generational changes. A must have ebook for any Porsche fanatic, this ebook is a reference book for Porsche enthusiasts. Discover all there is to know about the greatest Porsches ever made. All models are fully described and illustrated providing a definitive production history plus an accurate guide to original specs and equipment.