Info

Fault, Fault code

Possible causes, elimination, notes

Connect ohmmeter to connector A 12 and drive motor connector pin 3. Connect ohmmeter to connector D 10 and drive motor connector pin 4. Connect ohmmeter to connector D 2 and drive motor connector pin 5.

5. Check wire from connector C 8 to drive motor pin 1 for short to B+

6. Check wire from connector B 8 to drive motor pin 2 for short to B+

7. Check wire from connector A 12 to drive motor pin 3 for short to B+.

8. Check wire from connector D 10 to drive motor pin 4 for short to B+

9. Check wire from connector D 2 to drive motor pin 5 for short to B+

Test point 8

Motor of central

Signal implausible Fault code 27

Diagnosis conditions

No control module fault stored. No fault with supply voltage (5 volts).

Signal implausible

1. Check central valve for smooth operation.

2. Unplug connectors A, B, C and D from the heating/air-conditioning

Porsche Classic Models

Porsche Classic Models

The History of Porsche Cars through its generational changes. A must have ebook for any Porsche fanatic, this ebook is a reference book for Porsche enthusiasts. Discover all there is to know about the greatest Porsches ever made. All models are fully described and illustrated providing a definitive production history plus an accurate guide to original specs and equipment.