Info

Fault, fault code

Possible causes, elimination, notes

Test point 1

Data lead, air conditioner

Open circuit/short to

Signal disturbance Fault code 20

Open circuit/short to ground

1. Pull off plug II on the display and operator control unit.

2. Pull off plug C on the heater / A/C control unit.

3. Check lead from plug II pin 15 to plug C 12 for continuity

Note

The lead is routed via the 10-pole plug connection

Short to B+

1. Pull off plug II on the display and operator control unit.

2. Pull off plug C on the heater/ A/C control unit.

3. Check lead from plug II pin 15 to plug C 12 for short to B+.

Signal disturbance

Check wiring harness for short with other leads.

Fault, fault code

Possible causes, elimination, notes

Test point 2

Data lead, navigation

Open circuil/short to

Signal disturbance Fault code 21

Open circuit/short to ground

1. Pull off plug II on the display and operator control unit.

2. Pull off plug on the navigation unit.

3. Check lead from navigation unit plug pin 7 to plug II pin 17

Short to B+

Pull off plug II on the display and operator control unit.

2. Pull off plug on the navigation unit.

3. Check lead from navigation unit plug pin 7 to plug II pin 17

Signal disturbance

Check lead from navigation unit plug pin 7 to plug II pin 17

Porsche Classic Models

Porsche Classic Models

The History of Porsche Cars through its generational changes. A must have ebook for any Porsche fanatic, this ebook is a reference book for Porsche enthusiasts. Discover all there is to know about the greatest Porsches ever made. All models are fully described and illustrated providing a definitive production history plus an accurate guide to original specs and equipment.