Test point

Hall-effect sensor rear height adjustment, short circuit Fault code 15

This fault is stored in the following cases:

1. There is a short circuit in the wires to the Hall-effect sensor,

2. The Hall-effect sensor is faulty.

3. The control module is faulty. Elimination:

Disconnect plug from control module, check for continuity with

If a short circuit is found, check the sensor wires first.

If no fault is detected in the wire, replace the electric motor for

Once the cause of the fault has been found and eliminated, actuate the height adjustment switch. The text in the fault memory changes from present to not present if the cause of the fault has really

If the fault is still present, replace control module.

Test point 16

Lumbar pressure sensor

Fault code 18

This fault is stored in the following cases:

1. There is an open circuit in the wire to the lumbar pressure sensor.

2. The pressure sensor is faulty.

3. The control module is faulty, Elimination:

Check plug on control module for contact and damage Check wire to sensor for damage,

72 98 Diagnosis/troubleshooting, seat memory (System S 01)

Porsche Classic Models

Porsche Classic Models

The History of Porsche Cars through its generational changes. A must have ebook for any Porsche fanatic, this ebook is a reference book for Porsche enthusiasts. Discover all there is to know about the greatest Porsches ever made. All models are fully described and illustrated providing a definitive production history plus an accurate guide to original specs and equipment.