Test point 2

Door lock barrel closed, activated longer than 60 s Fault code 02

1. Pull off plug I on the alarm control module.

2. Disconnect plug connection X 11 (driver's side)

Note

This fault can also be caused by incorrect operation (door lock actuated toward "Closed" direction for longer than 60 seconds)

3. Disconnect the plug connection X 12 (passenger's side)

Fault. Fault code_Possible causes, elimination, notes____

4. Check the leads from the alarm control module plug I pin 35 to the door lock modules for short to ground.

Ohmmeter on alarm control module plug I pin 35 and ground. Display: °° Q

5. Check driver's side door lock module switch contact. Ohmmeter at plug connection X 11 pin A2 (sleeve side) and ground.

Door lock actuated towards "Closed".

6. Check passenger's side door lock module switch contact. Ohmmeter at plug connection X 12 pin A2 (sleeve side) and ground.

Door lock actuated towards "Closed".

Note

This fault can also be caused by incorrect operation (door lock actuated toward "Open" direction for longer than 60 seconds).

1. Pull off plug I on the alarm control module.

2. Disconnect plug connection X 11 (driver's side).

3. Disconnect the plug connection X 12 (passenger's side).

4. Check the leads from the alarm control module plug I pin 15 to the door lock modules for short to ground.

Porsche Classic Models

Porsche Classic Models

The History of Porsche Cars through its generational changes. A must have ebook for any Porsche fanatic, this ebook is a reference book for Porsche enthusiasts. Discover all there is to know about the greatest Porsches ever made. All models are fully described and illustrated providing a definitive production history plus an accurate guide to original specs and equipment.