Test point

Door lock barrel open/closed

1. Pull off plug I on the alarm control module.

2. Disconnect plug connection X 11 (driver's side).

3. Disconnect the plug connection X 12 (passenger's side).

Short to ground Fault code 06

4. Check the leads from the alarm control module plug I pin 35 to the door lock modules for short to ground.

Ohmmeter at alarm control module plug I pin 35 and ground

5. Check driver's side door lock module switch contact.

Ohmmeter at plug connection X 11 pin A4 (sleeve side) and ground Door lock not actuated. Display: q

Door lock actuated towards "Closed".

6. Check passenger's side door lock module switch contact. Ohmmeter at plug connection X 12 pin A4 (sleeve side) and ground.

Door lock actuated towards "Closed" Display: < 5 £2

7. Check the leads from the alarm control module plug I pin 15 to the door lock modules for short to ground.